The Allan variance (AVAR), also known as two-sample variance, is a measure of frequency stability in clocks, oscillators and amplifiers. It is named after David W. Allan. It is expressed mathematically as
The Allan deviation (ADEV) is the square root of Allan variance. It is also known as sigma-tau, and is expressed mathematically as
The M-sample variance is a measure of frequency stability using M samples, time T between measures and observation time . M-sample variance is expressed as
The Allan variance is intended to estimate stability due to noise processes and not that of systematic errors or imperfections such as frequency drift or temperature effects. The Allan variance and Allan deviation describe frequency stability. See also the section entitled "Interpretation of value" below.
There are also different adaptations or alterations of Allan variance, notably the modified Allan variance MAVAR or MVAR, the total variance, and the Hadamard variance. There also exist time stability variants such as time deviation TDEV or time variance TVAR. Allan variance and its variants have proven useful outside the scope of timekeeping and are a set of improved statistical tools to use whenever the noise processes are not unconditionally stable, thus a derivative exists.
The general M-sample variance remains important since it allows dead time in measurements and bias functions allows conversion into Allan variance values. Nevertheless, for most applications the special case of 2-sample, or "Allan variance" with is of greatest interest.