Glucagon rescue


Glucagon rescue is the emergency injection of glucagon in case of severe diabetic hypoglycemia. It is needed during seizures and/or unconsciousness by an insulin user who is unable at that point to help themselves. Glucagon will facilitate the release of stored glucose back into the bloodstream, raising the blood glucose level.

Rescue has been simplified by the development of the glucagon hypoglycemia rescue kit, consisting of:

At the first signs of hypoglycemia, an insulin user should treat it immediately by consuming carbohydrate to restore blood glucose to safe levels (thereby preventing progression to severe hypoglycemia). However, not all insulin users can feel and recognize the early signs, particularly when sleeping. This can quickly lead to an emergency resulting in unconsciousness, inability to swallow, seizures, and in extreme cases death. In the past, treatment consisted of intravenous delivery of dextrose (glucose) usually in the emergency room; however, the delay in treatment due to emergency response and transport to a medical facility is life-threatening.

The glucagon rescue kit facilitates rapid rescue by a simple injection, which does not require medical expertise, and can be done quickly and easily outside of a medical facility.

Glucagon rescue kits are manufactured by Novo Nordisk and Eli Lilly and Company. Novo Nordisk manufactures the GlucaGen HypoKit and Eli Lilly and Company manufactures the Glucagon Emergency Rescue Kit.

Glucagon must be reconstituted using a multi-step process that requires the administrator to use a prepared syringe containing an inactive compound and a sealed dosage bottle of glucagon. After the contents of the syringe are injected into the glucagon bottle, the administrator must determine if the reconstitution appears appropriate: clear with a water-like consistency. This is a subjective assessment. The solution must be drawn back into the syringe, the injection site cleaned with alcohol, and then injected with sufficient force into fatty tissue. Individuals who have not performed this procedure before are at a disadvantage increased by the potential for severe hypoglycemia

At the present time, there are no ready-made formulations of glucagon; within hours of reconstitution, the molecule will degrade into amyloid fibrils. Combined with the anxiety of performing a rescue is expense, bulkiness, and concerns over dosing correctly; fortunately, there is no biochemical way to overdose on intramuscularly injected glucagon.


...