A reinforced concrete column is a structural member designed to carry compressive loads, composed of concrete with an embedded steel frame to provide reinforcement. For design purposes, the columns are separated into two categories: short columns and slender columns.
The strength of short columns is controlled by the strength of the material and the geometry of the cross section. Reinforcing rebar is placed axially in the column to provide additional axial stiffness. Accounting for the additional stiffness of the steel, the nominal loading capacity Pn for the column in terms of the maximum compressive stress of the concrete fc', the yield stress of the steel fy, the gross cross section area of the column Ag, and the total cross section area of the steel rebar Ast
where the first term represents the load carried by the concrete and the second term represents the load carried by the steel. Because the yield strength of steel is an order of magnitude larger than that of concrete, a small addition of steel will greatly increase the strength of the column.
To give a conservative estimate and build redundancies into the final structural system, the ACI Building Code Requirements give a maximum reduced design load of where is the strength reduction factor for the type of column used. For spiral columns