*** Welcome to piglix ***

Real power


Power in an electric circuit is the rate of flow of energy past a given point of the circuit. In alternating current circuits, energy storage elements such as inductors and capacitors may result in periodic reversals of the direction of energy flow.

The portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction is known as active power (sometimes also called real power). The portion of power due to stored energy, which returns to the source in each cycle, is known as reactive power.

In a simple alternating current (AC) circuit consisting of a source and a linear load, both the current and voltage are sinusoidal. If the load is purely resistive, the two quantities reverse their polarity at the same time. At every instant the product of voltage and current is positive or zero, the result being that the direction of energy flow does not reverse. In this case, only active power is transferred.

If the load is purely reactive, then the voltage and current are 90 degrees out of phase. For two quarters of each cycle, the product of voltage and current is positive, but for the other two quarters, the product is negative, indicating that on average, exactly as much energy flows into the load as flows back out. There is no net energy flow over each half cycle. In this case, only reactive power flows: There is no net transfer of energy to the load, however, electrical power does flow along the wires and returns by flowing in reverse along the same wires. During its travels both from the power source to the reactive load and back to the power source, this purely reactive power flow loses energy to the line resistance. Practical loads have resistance as well as inductance, and/or capacitance, so both active and reactive power will flow to normal loads. Power engineers analyse the apparent power as being the magnitude of the vector sum of active and reactive power. Apparent power is the product of the rms values of voltage and current. Electrical engineers take apparent power into account when designing and operating power systems, because although the current associated with reactive power does no work at the load, (it heats the conductors and wastes energy) it still must be supplied by the power source. Conductors, transformers and generators must be sized to carry the total current, not just the current that does useful work. Failure to provide for the supply of sufficient reactive power in electrical grids can lead to lowered voltage levels and under certain operating conditions to the complete collapse of the network or blackout. Another consequence is that adding the apparent power for two loads will not accurately give the total power unless they have the same phase difference between current and voltage (the same power factor).


...
Wikipedia

...