In telecommunications, return loss is the loss of power in the signal returned/reflected by a discontinuity in a transmission line or optical fiber. This discontinuity can be a mismatch with the terminating load or with a device inserted in the line. It is usually expressed as a ratio in decibels (dB);
Return loss is related to both standing wave ratio (SWR) and reflection coefficient (Γ). Increasing return loss corresponds to lower SWR. Return loss is a measure of how well devices or lines are matched. A match is good if the return loss is high. A high return loss is desirable and results in a lower insertion loss.
Return loss is used in modern practice in preference to SWR because it has better resolution for small values of reflected wave.
Properly, loss quantities, when expressed in decibels, should be positive numbers. However, return loss has historically been expressed as a negative number, and this convention is still widely found in the literature.
The correct definition of return loss is the difference in dB between the incident power sent towards the Device Under Test (DUT) and the power reflected, resulting in a positive sign:
However taking the ratio of reflected to incident power results in a negative sign for return loss;
Return loss with a positive sign is identical to the magnitude of Γ when expressed in decibels but of opposite sign. That is, return loss with a negative sign is more properly called reflection coefficient. The S-parameter S11 from two-port network theory is frequently also called return loss, but is actually equal to Γ.
Caution is required when discussing increasing or decreasing return loss since these terms strictly have the opposite meaning when return loss is defined as a negative quantity.
In metallic conductor systems, reflections of a signal traveling down a conductor can occur at a discontinuity or impedance mismatch. The ratio of the amplitude of the reflected wave Vr to the amplitude of the incident wave Vi is known as the reflection coefficient .