Mine ventilation


Underground mine ventilation provides a flow of air to the underground workings of a mine of sufficient volume to dilute and remove dust and noxious gases (typically NOx, SO2, methane, CO2 and CO) and to regulate temperature. The source of these gases are equipment that runs on diesel engines, blasting with explosives, and the orebody itself. The largest component of the operating cost for mine ventilation is electricity to power the ventilation fans, which may account for one third of a typical underground mine's entire electrical power cost.

Flow-through ventilation is the main ventilation circuit for the mine. Air enters the mine from surface via a shaft, ventilation raise or adit. The air is distributed through the mine via internal ventilation raises and ramps, and flows are controlled by regulators and permanently mounted ventilation fans. An auxiliary ventilation system takes air from the flow-through system and distributes it to the mine workings via temporarily mounted ventilation fans, venturies and disposable fabric or steel ducting. Auxiliary fan and duct systems may be either forcing systems, where fresh air is pushed into mine headings, or exhausting systems that draw out contaminated air.

Sufficient volume of air is required for proper ventilation. A bulk of electric power is required for driving fans. By installing variable speed control air quantity can be optimized hence the power. at every place in the mine where persons are required to work or pass, the air does not contain less than 19% of oxygen or more than 0.5% of carbon dioxide or any noxious gas in quantity likely to affect the health of any person; the percentage of inflammable gas does not exceed 0.75% in the general body of the return air of any ventilating district and 1.25% in any place in the mine;

The volume (expressed in cubic feet per minute or cubic meters per second) of air required to ventilate an underground mine is determined by mining engineers based on a wide variety of parameters. In most countries minimum requirements are outlined by law, regulation or standards. However, in some developing countries the mandated ventilation requirement may be insufficient, and the mining company may have to increase the ventilation flow, in particular where ventilation may be required to cool the ambient temperature in a deep hot mine, however auto-compression must also be taken into account. as per CMR 130-2-(i) in every ventilating district, not less than six cubic metres per minute of air per personemployed in the district on the largest shift or not less than 2.5 cubic metres per minute of air per daily tonne output whichever is larger, passes along the last ventilation connection in the district which means the inbye-most gallery in the district along which the air passes;


...
Wikipedia

...