IEC 60601


IEC 60601 is a series of technical standards for the safety and effectiveness of medical electrical equipment, published by the International Electrotechnical Commission. First published in 1977 and regularly updated and restructured, as of 2011 it consists of a general standard, about 10 collateral standards, and about 60 particular standards.

The general standard IEC 60601-1 - Medical electrical equipment - Part 1: General requirements for basic safety and essential performance - gives general requirements of the series of standards. 60601 is a widely accepted benchmark for medical electrical equipment and compliance with IEC60601-1 has become a requirement for the commercialisation of electrical medical equipment in many countries. Many companies view compliance with IEC 60601-1 as a requirement for most markets.

National deviations of this series of standards exist which include country specific requirements; see e.g. UL or AAMI for US specifics.

The European EN and Canadian CSA versions of the standard are identical to the IEC standard.

In 2005, the third edition of IEC 60601-1 was published. It was the result of a comprehensive review of the second edition (dating from 1988). Some key changes are: the outline and the numbering scheme of the clauses and subclauses were changed, risk management was made much more relevant and the concept of essential performance was added. Currently (2012), the applicability of the second and third edition is somewhat overlapping depending on the products under consideration and the country/area of application. IEC 60601-1-11 (2010) must now be incorporated into the design and verification of a wide range of home use and point of care medical devices along with other applicable standards in the IEC 60601 3rd edition series.

The mandatory date for implementation of the EN European version of the standard is June 1, 2012. The US FDA requires the use of the standard on June 30, 2013, while Health Canada recently extended the required date from June 2012 to April 2013. The North American agencies will only require these standards for new device submissions, while the EU will take the more severe approach of requiring all applicable devices being placed on the market to consider the home healthcare standard.

Requirements of 60601-1 may be overridden or bypassed by specific language in the standards for a particular product. Collateral standards (numbered 60601-1-X) define the requirements for certain aspects of safety and performance, e.g. Electromagnetic Compatibility (IEC 60601-1-2) or Protection for diagnostic use of X-rays (IEC 60601-1-3). Particular standards (numbered 60601-2-X) define the requirements for specific products or specific measurements built into products, e.g. MR scanners (IEC 60601-2-33) or Electroencephalograms (IEC 60601-2-26). Collaterals and Particulars may have their own revisions which are different from the General Standard.


...