Bolometer


A bolometer is a device for measuring the power of incident electromagnetic radiation via the heating of a material with a temperature-dependent electrical resistance. It was invented in 1878 by the American astronomer Samuel Pierpont Langley.

A bolometer consists of an absorptive element, such as a thin layer of metal, connected to a thermal reservoir (a body of constant temperature) through a thermal link. The result is that any radiation impinging on the absorptive element raises its temperature above that of the reservoir – the greater the absorbed power, the higher the temperature. The intrinsic thermal time constant, which sets the speed of the detector, is equal to the ratio of the heat capacity of the absorptive element to the thermal conductance between the absorptive element and the reservoir. The temperature change can be measured directly with an attached resistive thermometer, or the resistance of the absorptive element itself can be used as a thermometer. Metal bolometers usually work without cooling. They are produced from thin foils or metal films. Today, most bolometers use semiconductor or superconductor absorptive elements rather than metals. These devices can be operated at cryogenic temperatures, enabling significantly greater sensitivity.

Bolometers are directly sensitive to the energy left inside the absorber. For this reason they can be used not only for ionizing particles and photons, but also for non-ionizing particles, any sort of radiation, and even to search for unknown forms of mass or energy (like dark matter); this lack of discrimination can also be a shortcoming. The most sensitive bolometers are very slow to reset (i.e., return to thermal equilibrium with the environment). On the other hand, compared to more conventional particle detectors, they are extremely efficient in energy resolution and in sensitivity. They are also known as thermal detectors.

The first bolometer used by Langley consisted of two platinum strips covered with lampblack. One strip was shielded from radiation and one exposed to it. The strips formed two branches of a Wheatstone bridge which was fitted with a sensitive galvanometer and connected to a battery. Electromagnetic radiation falling on the exposed strip would heat it and change its resistance. By 1880, Langley's bolometer was refined enough to detect thermal radiation from a cow a quarter of a mile away. This radiant-heat detector is sensitive to differences in temperature of one hundred-thousandth of a degree Celsius (0.00001 C). This instrument enabled him to thermally detect across a broad spectrum, noting all the chief Fraunhofer lines. He also discovered new atomic and molecular absorption lines in the invisible infrared portion of the electromagnetic spectrum. Nikola Tesla personally asked Dr. Langley if he could use his bolometer for his power transmission experiments in 1892. Thanks to that first use, he succeeded in making the first demonstration between West Point and his laboratory on Houston Street.


...
Wikipedia

...