Blalock–Thomas–Taussig shunt | |
---|---|
The arch of the aorta and its branches. In the Blalock–Thomas–Taussig shunt, blood from the subclavian artery or carotid artery (in red at the top) is redirected to the pulmonary artery (in blue near the center).
|
|
ICD-9-CM | 39.0 |
MeSH | D058366 |
The Blalock–Thomas–Taussig shunt (commonly called the Blalock–Taussig shunt) is a surgical procedure used to increase pulmonary blood flow for palliation in duct dependent cyanotic heart defects like pulmonary atresia, which are common causes of blue baby syndrome. In modern surgery, this procedure is temporarily used to direct blood flow to the lungs and relieve cyanosis while the infant is waiting for corrective or palliative surgery.
One branch of the subclavian artery or carotid artery is separated and connected with the pulmonary artery. The first area of application was tetralogy of Fallot.
The Blalock–Thomas-Taussig shunt may be used as the first step in the Fontan procedure.
The procedure is no longer in use in its original form. Now a length of artificial tubing, 3 to 4 millimeters in diameter, is sewn between either the subclavian or the carotid artery and the corresponding side branch of the pulmonary artery, thus obviating the need to cut off blood supply and making it easier to regulate the blood flow to the lungs. Some centers now use a shunt directly from the right ventricle to the pulmonary artery, a Sano shunt. This is done to avoid the reduced diastolic blood flow in the coronary circulation associated with the Blalock–Taussig shunt.
The original procedure was named for Alfred Blalock, surgeon, Baltimore (1899–1964), Helen B. Taussig, cardiologist, Baltimore/Boston (1898–1986) and Vivien Thomas (1910–1985) who was at that time Blalock's laboratory technician, developed the procedure. Taussig, who treated hundreds of infants and children with this disorder, had observed that children with a cyanotic heart defect and a patent ductus arteriosus (PDA) lived longer than those without the PDA. It therefore seemed to her that a shunt which mimicked the function of a PDA might relieve the tetralogy patients' poor oxygenation. In 1943, having broached the possibility of a surgical solution to Robert Gross of Boston without success, Taussig approached Blalock and Thomas in their Hopkins laboratory in 1943. According to the account of the original consultation between the three provided in Vivien Thomas' 1985 autobiography Partners of the Heart, Taussig carefully described the anomaly of Tetralogy of Fallot, but made no suggestion about the specific surgical correction required, observing merely that it should be possible to get more blood to the lungs, "as a plumber changes pipes around." Although Taussig was not aware of it at that time, Blalock and Thomas had already experimented with such an anastomosis, one that Blalock had conceived years earlier for a different purpose but which had the unanticipated effect of re-routing blood to the lungs. The operation involved the joining of the subclavian artery to the pulmonary artery. After meeting with Taussig, the two men set about perfecting the operation in the animal lab, with Thomas performing the subclavian-to-pulmonary anastomosis alone in some 200 laboratory dogs, then adapting the instruments for the first human surgery from those used on the experimental animals and coaching Blalock through the first 100 operations on infants.