Flyback converter


The flyback converter is used in both AC/DC and DC/DC conversion with galvanic isolation between the input and any outputs. The flyback converter is a buck-boost converter with the inductor split to form a transformer, so that the voltage ratios are multiplied with an additional advantage of isolation. When driving for example a plasma lamp or a voltage multiplier the rectifying diode of the boost converter is left out and the device is called a flyback transformer.

The schematic of a flyback converter can be seen in Fig. 1. It is equivalent to that of a buck-boost converter, with the inductor split to form a transformer. Therefore, the operating principle of both converters is very similar:

The operation of storing energy in the transformer before transferring to the output of the converter allows the topology to easily generate multiple outputs with little additional circuitry, although the output voltages have to be able to match each other through the turns ratio. Also there is a need for a controlling rail which has to be loaded before load is applied to the uncontrolled rails, this is to allow the PWM to open up and supply enough energy to the transformer.

The flyback converter is an isolated power converter. The two prevailing control schemes are voltage mode control and current mode control (in the majority of cases current mode control needs to be dominant for stability during operation). Both require a signal related to the output voltage. There are three common ways to generate this voltage. The first is to use an on the secondary circuitry to send a signal to the controller. The second is to wind a separate winding on the coil and rely on the cross regulation of the design. The third consists on sampling the voltage amplitude on the primary side, during the discharge, referenced to the standing primary DC voltage.

The first technique involving an optocoupler has been used to obtain tight voltage and current regulation, whereas the second approach has been developed for cost-sensitive applications where the output does not need to be as tightly controlled, but up to 11 components including the optocoupler could be eliminated from the overall design. Also, in applications where reliability is critical, optocouplers can be detrimental to the MTBF (Mean Time Between Failure) calculations. The third technique, primary-side sensing, can be as accurate as the first and more economical than the second, yet requires a minimum load so that the discharge-event keeps occurring, providing the opportunities to sample the 1:N secondary voltage at the primary winding (during Tdischarge, as per Fig3).


...