Limit state design


Limit state design (LSD), also known as load and resistance factor design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. The condition may refer to a degree of loading or other actions on the structure, while the criteria refer to structural integrity, fitness for use, durability or other design requirements. A structure designed by LSD is proportioned to sustain all actions likely to occur during its design life, and to remain fit for use, with an appropriate level of reliability for each limit state. Building codes based on LSD implicitly define the appropriate levels of reliability by their prescriptions.

The method of limit state design, developed in the USSR and based on research led by Professor N.S. Streletski, was introduced in USSR building regulations in 1955.

Limit state design requires the structure to satisfy two principal criteria: the ultimate limit state (ULS) and the serviceability limit state (SLS).

Any design process involves a number of assumptions. The loads to which a structure will be subjected must be estimated, sizes of members to check must be chosen and design criteria must be selected. All engineering design criteria have a common goal: that of ensuring a safe structure and ensuring the functionality of the structure.

A clear distinction is made between the Ultimate State (US) and the Ultimate Limit State (ULS). The US is a physical situation that involves either excessive deformations leading and approaching collapse of the component under consideration or the structure as a whole, as relevant, or deformations exceeding pre agreed values. It involves of course considerable inelastic (plastic) behavior of the structural scheme and residual deformations. While the ULS is not a physical situation but rather an agreed computational condition that must be fulfilled, among other additional criteria, in order to comply with the engineering demands for strength and stability under design loads. The ULS condition is computationally checked at a certain point along the behavior function of the structural scheme, located at the upper part of its elastic zone at approximately 15% lower than the elastic limit. That means that the ULS is a purely elastic condition, located on the behavior function far below the real Ultimate point, which is located deeply within the plastic zone. The rationale for choosing the ULS at the upper part of the elastic zone is that as long as the ULS design criteria is fulfilled, the structure will behave in the same way under repetitive loadings, and as long as it keeps this way, it proves that the level of safety and reliability assumed as the basis for this design is properly maintained and justified, (following the probabilistic safety approach). A structure is deemed to satisfy the ultimate limit state criterion if all factored bending, shear and tensile or compressive stresses are below the factored resistances calculated for the section under consideration. The factored stresses referred to are found by applying Magnification Factors to the loads on the section. Reduction Factors are applied to determine the various factored resistances of the section.


...
Wikipedia

...