80 Plus


80 Plus (trademarked 80 PLUS) is a voluntary certification program intended to promote efficient energy use in computer power supply units (PSUs). Launched in 2004 by Ecos Consulting, it certifies products that have more than 80% energy efficiency at 20%, 50% and 100% of rated load, and a power factor of 0.9 or greater at 100% load. Such PSUs waste 20% or less electric energy as heat at the specified load levels, reducing electricity use and bills compared to less efficient PSUs.

Redundancy is typically used in data centers.

For the higher certification levels, the requirement of 0.9 or better power factor was extended to apply to 20% and 50% load levels, as well as at 100% load. The Platinum level requires 0.95 or better power factor for servers.

The Climate Savers Computing Initiative efficiency level targets for workstations for 2007 through 2011, correspond to the 80 Plus certification levels. From July 2007 through June 2008, basic 80 Plus level (Energy Star 4.0). For the next year target is 80 Plus Bronze level, the following year 80 Plus Silver, then 80 Plus Gold, and finally Platinum.

There have been instances where companies claim or imply that their supplies are 80 Plus when they have not been certified, and in some cases do not meet the requirements. When a company resells an OEM power supply under a new name it must be certified under the new name and company, even if the OEM supply is certified. In some instances, a reseller has claimed a higher wattage than the supply can deliver – in which case the reseller's supply would not meet 80 Plus requirements. The 80 Plus web site has a list of all certified supplies, so it is possible to confirm that a supply really meets the requirements.

Although some power supply manufacturers name their products with similar names, such as "85 Plus", there is no such official certification or standard.

The efficiency of a computer power supply is its output power divided by its input power; the remaining input power is converted into heat. For instance, a 600-watt power supply with 60% efficiency running at full load would draw 1000 W from the mains and would therefore waste 400 W as heat. On the other hand, a 600-watt power supply with 80% efficiency running at full load would draw 750 W from the mains and would therefore waste only 150 W as heat.

For a given power supply, efficiency varies depending on how much power is being delivered. Supplies are typically most efficient at between half and three quarters load, much less efficient at low load, and somewhat less efficient at maximum load. Older ATX power supplies were typically 60% to 75% efficient. To qualify for 80 Plus, a power supply must achieve at least 80% efficiency at three specified loads (20%, 50% and 100% of maximum rated power). However, 80 Plus supplies may still be less than 80% efficient at lower loads. For instance, an 80 Plus, 520 watt supply could still be 70% or less efficient at 60 watts (a typical idle power for a desktop computer). Thus it is still important to select a supply with capacity appropriate to the device being powered.


...